排序方式: 共有60条查询结果,搜索用时 265 毫秒
11.
H. S. Erkan G. O. Engin B. Kulil G. Gunalp 《International Journal of Environmental Science and Technology》2017,14(5):933-942
The properties of activated sludge are very important in a membrane bioreactor (MBR) in terms of membrane fouling. The most important parameters affecting the membrane fouling can be listed as mixed liquor suspended solid (MLSS) concentration, soluble microbial products (SMPs), extracellular polymeric substances (EPSs), floc size, aeration and viscosity of both supernatant and activated sludge. The COD/TKN ratio also affects the physical properties of sludge in MBR system. This study aimed to investigate the effect of chemical oxygen demand-to-total Kjeldahl nitrogen (COD/TKN) ratio of feed wastewater treated in an MBR on biological components of activated sludge. The activated sludge characteristics were determined by quantitative analyses such as MLSS, EPS, SMP, floc size distribution, zeta potential, relative hydrophobicity and capillary suction time in a submerged MBR treating simulated wastewater having different COD/TKN ratios (16, 56 and 107). The COD and TKN removal efficiencies were found to be almost equal in the sMBRs having different COD/TKN ratios. However, it was seen that the EPS content and SMP concentration in the supernatant increased with increasing COD/TKN ratio. The results indicated that the COD/TKN ratio of feed should be considered as an effective parameter on activated sludge properties in sMBR systems. 相似文献
12.
13.
Celalettin Özdemir Hayrunnisa Tezcan Serkan Sahinkaya Erkan Kalipci 《洁净——土壤、空气、水》2010,38(12):1152-1158
The removal of chemical oxygen demand (COD) and phenol from olive oil mill wastewaters (OOMW) was investigated experimentally by using conventional Fenton (CFP) and Fenton type processes (FTP) with zero valent iron (ZVI). Different operational parameters such as initial pH, Fe2+, Fe0, and H2O2 concentrations were examined. Kinetic studies in terms of COD and phenol removals for both CFP and FTP were performed. The original pH value (4.6) of OOMW for CFP was found as the optimum pH. The determined optimum conditions are [Fe2+] = 1500 mg L?1, [H2O2] = 1750 mg L?1, and pH = 4.6 for CFP; [Fe0] = 2000 mg L?1, [H2O2] = 2000 mg L?1, and pH = 3 for FTP. 82.4% COD and 62% phenol removals were performed under the optimum conditions by CFP, while 82% COD and 63.4% phenol were removed by FTP. According to the results of kinetic studies, it was observed that COD and phenol were removed by FTP more rapidly, compared to CFP. Consequently, it was determined that both CFP and FTP were effective processes for the pretreatment of OOMW. 相似文献
14.
This paper presents a field study conducted in northwest Turkey and characterizes the NH3 concentration and emission measured in summer season from three chicken farms. The influence of environmental conditions on NH3 concentration and emission was also investigated in this study. Ammonia concentration, temperature, relative humidity and airflow rate were continuously recorded for four sequential days. The environmental conditions were measured using a multifunction temperature and humidity‐meter with a hot wire probe. Portable multiple gas detectors with electro‐chemical sensors were used to measure NH3 concentration. The NH3 emission rates for houses were calculated by multiplying simultaneously measured NH3 concentrations and air flow rates. The average daily mean (ADM) house concentrations of house 1 (H1), house 2 (H2), and house 3 (H3) were measured as 4.43, 3.71, and 6.20 ppm, respectively. NH3 concentration was inversely proportional to temperature (r = ?0.279), relative humidity (r = ?0.063) and airflow rate (r = ?0.554) for all monitored houses. The ADM house NH3 emission was 135 g/(h house) for H1, 255 g/(h house) for H2, and 117 g/(h house) for H3. The combined average emission rate in this study (0.26 g/(d bird)) was lower than the emission rate measured in chicken farms in the USA. However, our results were comparable to rates calculated in European studies because house design, ventilation system and bird diet applied in Turkish chicken farms are very similar to those employed in European countries. The NH3 emissions were significantly correlated to NH3 concentrations (r = 0.45, p ≤ 0.001) and airflow rates (r = 0.97, p ≤ 0.001). A clear diurnal pattern was obtained for NH3 concentrations rather than NH3 emissions at the end of the study. 相似文献
15.
Comparative analysis of fuzzy inference systems for water consumption time series prediction 总被引:1,自引:0,他引:1
Two types of fuzzy inference systems (FIS) are used for predicting municipal water consumption time series. The FISs used include an adaptive neuro-fuzzy inference system (ANFIS) and a Mamdani fuzzy inference systems (MFIS). The prediction models are constructed based on the combination of the antecedent values of water consumptions. The performance of ANFIS and MFIS models in training and testing phases are compared with the observations and the best fit model is identified according to the selected performance criteria. The results demonstrated that the ANFIS model is superior to MFIS models and can be successfully applied for prediction of water consumption time series. 相似文献
16.
17.
Is there a limit to bioretention effectiveness? Evaluation of stormwater bioretention treatment using a lumped urban ecohydrologic model and ecologically based design criteria 下载免费PDF全文
Olivia M. Wright Erkan Istanbulluoglu Richard R. Horner Curtis L. DeGasperi Jim Simmonds 《水文研究》2018,32(15):2318-2334
In this study, we developed the urban ecohydrology model (UEM) to investigate the role of bioretention on watershed water balance, runoff production, and streamflow variability. UEM partitions the land surface into pervious, impervious, and bioretention cell fractions. Soil moisture and vegetation dynamics are simulated in pervious areas and bioretention cells using a lumped ecohydrological approach. Bioretention cells receive runoff from a fraction of impervious areas. The model is calibrated in an urban headwater catchment near Seattle, WA, USA, using hourly weather data and streamflow observations for 3 years. The calibrated model is first used to investigate the relationship between streamflow variability and bioretention cell size that receives runoff from different values of impervious area in the watershed. Streamflow variability is quantified by 2 indices, high pulse count (HPC), which quantifies the number of flow high pulses in a water year above a threshold, and high pulse range (HPR), which defines the time over which the pulses occurred. Low values of these indices are associated with improved stream health. The effectiveness of the modelled bioretention facilities are measured by their influence on reducing HPC and HPR and on flow duration curves in comparison with modelled fully forested conditions. We used UEM to examine the effectiveness of bioretention cells under rainfall regimes that are wetter and drier than the study area in an effort to understand linkages between the degree of urbanization, climate, and design bioretention cell size to improve inferred stream health conditions. In all model simulations, limits to the reduction of HPC and HPR indicators were reached as the size of bioretention cells grew. Bioretention was more effective as the rainfall regime gets drier. Results may guide bioretention design practices and future studies to explore climate change impacts on bioretention design and management. 相似文献
18.
Mount Hasan is a double-peaked stratovolcano, located in Central Anatolia, Turkey. The magmas erupted from this multi-caldera complex range from basalt to rhyolite, but are dominated by andesite and dacite. Two terminal cones (Big Mt. Hasan and Small Mt. Hasan) culminate at 3253 m and 3069 m respectively. There are four evolutionary stages in the history of the volcanic complex (stage 1: Kecikalesi volcano, 13 Ma, stage 2: Palaeovolcano, 7 Ma, stage 3: Mesovolcano and stage 4: Neovolcano). The eruptive products consist of lava flows, lava domes, and pyroclastic rocks. The later include ignimbrites, phreatomagmatic intrusive breccias and nuées ardentes, sometimes reworked as lahars. The total volume is estimated to be 354 km3, the area extent 760 km2. Textural and mineralogical data suggest that both magma mixing and fractional crystallization were involved in the generation of the andesites and dacites. The magmas erupted from the central volcanoes show a transition with time from tholeite to calc-alkaline. Three generations of basaltic strombolian cones and lava flows were emplaced contemporaneously with the central volcanoes. The corresponding lavas are alkaline with a sodic tendency. 相似文献
19.
The Afyon stratovolcano exhibits lamprophyric rocks, emplaced as hydrovolcanic products, aphanitic lava flows and dyke intrusions, during the final stages of volcanic activity. Most of the Afyon volcanics belong to the silica-saturated alkaline suite, as potassic trachyandesites and trachytes, while the products of the latest activity are lamproitic lamprophyres (jumillite, orendite, verite, fitztroyite) and alkaline lamprophyres (campto-sannaite, sannaite, hyalo-monchiquite, analcime–monchiquite). Afyon lamprophyres exhibit LILE and Zr enrichments, related to mantle metasomatism. 相似文献
20.
Natural Resources Research - It is common to use synthetic fibers to increase the strength of engineering materials. Fibers obtained from rocks have also started to take their place in composite... 相似文献